add: error message for wbem
This commit is contained in:
parent
5c7ac0a752
commit
6cf2a46253
@ -16,13 +16,16 @@ keywords:
|
||||
]
|
||||
---
|
||||
|
||||
## 1. Missing Windows Management Instrumentation Command-line (WMIC)
|
||||
## 1. Issue: Missing Windows Management Instrumentation Command-line (WMIC)
|
||||
|
||||
Encountering an stuck on loading model issue in Jan is caused by errors related the `Windows Management Instrumentation Command-line (WMIC)` path not being included in the system's PATH environment variable.
|
||||
|
||||
It can be resolved through the following steps:
|
||||
Error message:
|
||||
```
|
||||
index.js:47 Uncaught (in promise) Error: Error invoking remote method 'invokeExtensionFunc': Error: Command failed: WMIC CPU Get NumberOfCores
|
||||
```
|
||||
|
||||
### Adding WMIC Path to Environment Variables:
|
||||
It can be resolved through the following steps:
|
||||
|
||||
1. **Open System Properties:**
|
||||
- Press `Windows key + R`.
|
||||
@ -47,7 +50,7 @@ It can be resolved through the following steps:
|
||||
- Run `where wmic` to verify. Expected output: `C:\Windows\System32\wbem\WMIC.exe`.
|
||||
|
||||
|
||||
## 2. CPU without AVX
|
||||
## 2. Issue: Model Loading Stuck Due to CPU without AVX
|
||||
|
||||
Encountering an issue with models stuck on loading in Jan can be due to the use of older generation CPUs that do not support Advanced Vector Extensions (AVX).
|
||||
|
||||
|
||||